Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Deutsch |Pусский |
| No.13641418

- Product Categories
- Liquid Turbine Flowmeter
- Gas turbine flowmeter
- Vortex Flowmeter
- Electromagnetic Flowmeter
- Metal tube
- Orifice flowmeter
- Friendly Links
Information Name: | KH / LWGY2 inch silicone flowmeter |
Published: | 2015-02-26 |
Validity: | 365 |
Specifications: | |
Quantity: | 99.00 |
Price Description: | |
Detailed Product Description: | Flow meters, level gauges are the main products Huai 安科昊 Automation Instrumentation Co., Ltd., and if there is any need, please contact us, Tel: 18901403300 / 0517-83309835 Contact: Wu Jingli. Silicone meter Introduction: KH-LWGY silicone oil flow metering meter main types of flowmeters are widely used measurement of ethanol in petroleum, chemical, metallurgy, research and other fields, the control system. It uses a multi-blade rotor (turbine) the average velocity of the fluid feel, and deduced from the flow meter or total. It is generally cited by the sensor and the display device composed of two parts, can also be made integral. LW silicone meter lead and volumetric flow meter, flow meter flowmeter called three repeatability, precision best products, as one of the ten types of flow meters, and its products have been developed for multi-species, multi-series production scale. Silicone meter works: silicone meter Schematic 1. A turbine placed in the center of the pipe, both ends supported by bearings. When the fluid through the pipe, the impact of turbine blades, the turbine generates driving torque, the friction torque and the turbine customer resistance torque generated by rotation of the fluid. In a certain flow range, the viscosity of the fluid medium to a certain rotational angular velocity is proportional to the flow rate of the fluid turbine. To be detected by the rotational speed of the turbine is mounted outside the case of the sensing coil. When the turbine blade cutting charge by the housing of a long line of magnetic force magnet, can cause changes in the magnetic flux in the sensing coil. Sensing coil detects the change in magnetic flux periodic signal into the preamplifier, the signal amplification, shaping, resulting in the flow rate is proportional to the pulse signal into the unit converter circuit and flow totalizer get and display the cumulative flow value; At the same time will pulse signal into a frequency-current converter circuit converts the pulse signal into an analog current amount, and then pointed out that the instantaneous flow values. Silicone oil flowmeter structure: the generic principles silicone block diagram shown in Figure 2 the flow meter. Fluid flows into the housing from the inlet, through a pair of bearing brackets fixed to the tube central axis, a turbine mounted on bearings. Rectifying plate provided with radial upstream and downstream of the turbine in the bracket, to act as guides for the fluid, in order to avoid effect of changes of spin fluid turbine blade angle. In the top of the turbine housing is equipped with an external sensor coil, the magnetic flux change signal is received. Silicone flowmeter features: 1. silicone flowmeter pressure loss, the impeller prevent corrosion; 2. the use of advanced ultra-low-power single-chip microprocessor technology, machine functions, low power consumption, superior performance. 3. silicone precision flowmeter with nonlinear compensation function of intelligent traffic monitor. Correction formula accuracy of better than ± 0.02% 4. meter factor can be the key online settings, and can be displayed on the LCD screen, LCD screen, clear and intuitive, reliability silicone oil flow meter 5. EEPROM cumulative flow meter factor brownout protection, 6. Protection of longer than 10 years of high-performance MCU meter silicone central processor, complete data acquisition and processing display output, the cumulative flow instantaneous flow 7. screen display with easy to achieve human-machine interface, a standard form 485 for data transmission. 8. all-carbide (WC) cantilever structure shielded bearings, bearing and pressure bearing assembly rotates in one, greatly improving the bearing life, and in a small amount of sand and dirt media work. 9. silicone flowmeters used 1Cr18Ni9Ti stainless steel structure, (turbine using 2Cr13) good corrosion resistance. 10. easy maintenance, have since rectified the structure of small, lightweight, simple structure, combining them in a short time apart and 11 meter silicone internal cleaning simple. 12. there is a strong anti-magnetic interference and vibration capability, reliable performance, long life 13. The limit velocity is low, wide measuring range, 14. The site display type LCD display is clear and intuitive, low-power, 3V lithium battery can run continuously 5 above, the 15 meter resistant silicone, silicone oil applied to acid solution flowmeter technology parameters: Schedule nominal diameter: Pipeline: DN4 ~ DN200 plug-in: DN100 ~ DN2000 Accuracy: Pipeline: ± 0.5 级, ± 1.0 Plug-in: ± 1.5 级, ± 2.5 class environment temperature: -20 ℃ ~ 50 ℃ Medium temperature: Measurement of liquid: -20 ℃ ~ 120 ℃ Measuring gas: -20 ℃ ~ 80 ℃ Atmospheric pressure: 86KPa ~ 106KPa Nominal : 1.6 Mpa, 2.5Mpa, 6.4Mpa, 25Mpa Explosion levels: ExdIIBT4 Connection: threaded connection, flange clamp, flange, plug-in, such as straight pipe requirements: Gas: Upstream straight pipe should ≥10DN, downstream straight pipe should ≥5DN liquid: upstream straight pipe should ≥20DN, downstream straight pipe should ≥5DN plug-in: upstream straight pipe should ≥20DS, downstream straight pipe should ≥7DS (DS was measured inside diameter of the pipe) Display: (1) Remote Display: pulse output, the current output (with indicator) (2) on-site display: 8 LCD display cumulative flow units (m3) 4-digit LCD display instantaneous flow units (m3 / h), battery power, frequency, flow rate (3) temperature and pressure compensation type: A, shows the standard instantaneous flow rate and total flow standard B, the current pressure, temperature, battery voltage output function: (1) pulse output, pp value is determined by the power supply (2) 4 ~ 20mA two-wire current Output (3) per unit volume of the original pulse output and pulse output sensors (4) RS485 communication interface with power supply: (1) DC5 ~ 24V (2) standard 3V lithium batteries installed in the inside of the instrument can be used continuously for more than eight years ( 3) temperature and pressure compensation type 3V lithium batteries installed in the instrument can be used continuously for more than four years of internal transmission distance: distance from the sensor to the display device up to 500m silicone meter installation requirements: 1, silicone oil flow meter installation flange connection, threaded connections and Clamp-on; 2, the liquid flow direction should be installed with the sensor housing indicates the direction of the arrow consistent flow and upstream straight pipe should ≥6DS, downstream straight pipe should ≥5DS (DS was measured for the pipe diameter). 3, the sensor should be away from the external magnetic field, if not avoided, should take the necessary measures; 4, in order not to affect the maintenance of normal transmission fluid, you should install a bypass pipe (Figure IV) at the outer ends of the straight pipe sensor; 5 When the sensor outdoor installation, please do waterproof amplifier plugs; 6, sensor and display instrument wiring, should be selected according to the power amplifier wiring. |
Admin>>>
You are the 75109 visitor
Copyright © GuangDong ICP No. 10089450, Huai An Kehao Automation Instrumentation Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 75109 visitor
Copyright © GuangDong ICP No. 10089450, Huai An Kehao Automation Instrumentation Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility