Information Name: | Air conditioning water meter / liquid flow meter Branch Hao factory direct |
Published: | 2015-01-21 |
Validity: | 365 |
Specifications: | |
Quantity: | 99.00 |
Price Description: | |
Detailed Product Description: | KH-LDE conditioned water meter is my plant using the most advanced technology research and development of all-around smart meter, with older analog or non-intelligent electromagnetic flowmeter has a very big difference, especially in the measurement accuracy, reliability, stability, functionality and other aspects of life. KH-LDE conditioning water flow meter is a precision, high reliability and long life flow meter, so the design of product structure, selection, formulation technology, manufacturing, assembly and factory testing process every step we are very careful attention, we also to design a set of domestic most advanced, dedicated to the electromagnetic flowmeter production equipment and real traffic flow calibration device, which can effectively guarantee the software and hardware on a long-term, high-quality products. KH-LDE conditioned water meter specifically designed with a backlit LCD display wide temperature range of Chinese, functional and practical, intuitive display, easy operation, you can reduce other electromagnetic flowmeter English menu the inconvenience. 4-6 In addition, we design exclusive multi-electrode structure, to further ensure the accuracy and any time without grounding ring, reducing the volume and the meter installation and maintenance of trouble. Sewage electromagnetic flowmeter / Φ100mm air conditioning water meter / Φ100mm corrosion electromagnetic flowmeter / Φ150mm advantages: 1, debris, fibers do not affect the measurement 2, PTFE lining 3 corrosion, anti-bacterial anti-sticking type electrode 4, positive and negative 5 cumulative flow metering, intelligent self-rash-off function advantages: 1, the magnetic field strength is increased five-fold 2, specializes in ultra-low flow velocity measurement 3, the input impedance of 4 ohms up to 15 megabytes of built-in magnet 5 large, high-current excitation advantages: 1, four safety grounding electrode body 2, Hastelloy C alloy electrode 3, PTFE lined acid and alkali resistant 4, extend the life of five stainless steel housing, density conversion function, easily calculate quality diving Electromagnetic Flowmeter / Φ200mm high temperature electromagnetic flowmeter / Φ300mm small caliber electromagnetic flowmeter / Φ10mm advantages: 1, orange enameled dive February 10, protection class: IP68 3, hermetically sealed plastic irrigation technology, Some do not leak advantages: 1, high temperature of 200 degrees 2, the choice of high-temperature enameled ring 3, with net skeleton lined advantages: 1, the minimum flow can be measured to 20.0L / h 2, high pressure extrapolation electrode 3, responsive, stable zero air conditioning water meter Features: ◆ measurement accuracy is not impact of fluid density, viscosity, temperature, pressure and electrical conductivity changes, the sensor sensing the voltage signal and a linear relationship between the average velocity, and therefore high accuracy. ◆ unimpeded flow measurement pipe fittings, so there is no additional pressure loss; measurement tube no moving parts, so very long sensor life. ◆ Because the induced voltage signal is filled in the whole space formed in the magnetic field, is the average of the surface pipe set, so the sensor straight pipe for a shorter length of 5 times the pipe diameter. ◆ sensor portion only liner and electrode in contact with the measured liquid, as long as a reasonable choice of electrode and lining material can be resistant to corrosion and abrasion. ◆ LDE converter uses the latest most advanced microcontroller (MCU) and surface mount technology (SMT), reliable performance, high accuracy, low power consumption, zero stability, convenient parameter setting. Click the Chinese display LCD, display the cumulative flow, instantaneous flow velocity, flow percentage and so on. ◆ Bi-directional measurement system can measure forward flow, reverse flow. Using a special production process and quality materials to ensure product performance remains stable over a long time. Air conditioning water flow measurement principle: Measuring principle KH-LDE-type air-conditioning water flow meter is based on Faraday's law: conductive liquid cutting magnetic field lines, the potential induced in the conductor in a magnetic field, the EMF E is: E = KBVD wherein: when the average flow velocity D ---- measuring the inside diameter of pipe cross-section measuring flow meter constant K ---- B ---- V ---- measuring magnetic induction within the pipe cross-section, the conductive liquid at a speed V flowing through a magnetic field perpendicular to the flow direction, the flow of conductive liquid induces a voltage proportional to the average velocity, the induced voltage signal through an electrode which two or more direct contact with the liquid are detected, and sent through the cable converter through intelligent processing, and LCD display or converted into a standard signal output 4 ~ 20ma and 0-1khz. How correct selection: instrument selection is very important instrumentation work, the data indicate that the instrument has practical application in fault 2/3 meter selection is wrong or incorrect installation caused, please pay special attention . ◆ collect data: 1. 2. The maximum flow measured fluid composition, the minimum flow 3. The maximum working pressure maximum temperature, minimum temperature ◆ measured fluid must have a certain conductivity, electrical conductivity> 5μS / CM maximum flow and minimum traffic must comply with the following table count: mm caliber flow range m3 / h mm caliber flow range m3 / h φ15 0.0636 ~ 6.36 φ450 57.23 ~ 5722.65 φ20 0.11 ~ 11.30 φ500 70.65 ~ 7065.00 φ25 0.18 ~ 17.66 φ600 101.74 ~ 10173.6 φ40 0.45 ~ 45.22 φ700 138.47 ~ 13847.4 φ50 0.71 ~ 70.65 φ800 180.86 ~ 18086.4 φ65 1.19 ~ 119.4 φ900 228.91 ~ 22890.6 φ80 1.81 ~ 180.86 φ1000 406.94 ~ 40694.4 φ100 2.83 ~ 282.60 φ1200 553.90 ~ 55389.6 φ150 6.36 ~ 635.85 φ1600 723.46 ~ 72345.6 φ200 11.3 ~ 1130.4 φ1800 915.62 ~ 91562.4 φ250 17.66 ~ 176.25. φ2000 1130.4 ~ 113040.00 φ300 25.43 ~ 2543.40 φ2200 1367.78 ~ 136778.4 φ350 34.62 ~ 3461.85 φ2400 1627.78 ~ 162777.6 φ400 45.22 ~ 4521.6 φ2600 1910.38 ~ 191037.6 ◆ actual maximum working pressure must be less than the rated working pressure flowmeter. ◆ The maximum operating temperature and the minimum temperature must meet the requirements specified temperature meter. ◆ determine whether there exists a negative pressure situation. You can select the appropriate electromagnetic flowmeter according to the table in the flow, and if the inner diameter of the electromagnetic flowmeter selection process and the inner diameter of the pipe is now inconsistent, should shrink tube or flaring. ◆ If the pipes shrink tube should be considered due to the reduction of the pressure loss caused will affect the process. ◆ consider the price, you can choose a smaller caliber electromagnetic flowmeter, the relative reduction in investment. ◆ When measuring clean water flow rate when the economy 1.5-3m / s, measured at a solution and crystallization, should be properly increase the flow rate, 3-4m / s is appropriate, play a self cleaning action to prevent the adhesion of deposition; measuring pulp ◆ consumption when grinding fluids, etc., should be appropriately reduced velocity, 1.0-2m / s is appropriate, in order to reduce wear on the lining and the ground electrode. Practical applications rarely exceed 7m / s, more than 10m / s is even more rare. |
Admin>>>
You are the 75109 visitor
Copyright © GuangDong ICP No. 10089450, Huai An Kehao Automation Instrumentation Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 75109 visitor
Copyright © GuangDong ICP No. 10089450, Huai An Kehao Automation Instrumentation Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility